C2070 Delta E+Delta E+ · SFU

Architecture

Single OSeMOSYS REGION (CAN); geography is encoded in fixed-width two-character zone codes. Every transmission link is an ordinary technology — the OSeMOSYS Trade mechanism is not used.

Why transmission is technologies

Technologies already provide losses, costs, maximum capacities, lifetimes and investment. Stock OSeMOSYS Trade is unbounded, cost-free and lossless, so rebuilding those features on it would be wasted effort.

Zones

13 zones across 9 provinces; the four largest provinces are split in two.

CodeProvinceZone
B1British ColumbiaSouth Coast / Lower Mainland
B2British ColumbiaInterior & North
A1AlbertaCalgary–Edmonton corridor
A2AlbertaNorth (oil sands)
S1SaskatchewanSaskatchewan
M1ManitobaManitoba
O1OntarioSouthern Ontario
O2OntarioNorthern Ontario
Q1QuebecSouthern Quebec
Q2QuebecNorthern Quebec (hydro)
T1Atlantic (NB+NS+PE)Atlantic
L1Newfoundland & LabradorNewfoundland & Labrador
N1North (YT+NT+NU)North (territories)

Transmission

24 technologies — 8 intra-provincial and 16 interprovincial (both directions per link). Capacity, cost and losses come from the technology formulation, so expansion is endogenous.

LinkCapacityKind
B1↔B23.0 GWintra-provincial
A1↔A22.5 GWintra-provincial
O1↔O24.0 GWintra-provincial
Q1↔Q26.0 GWintra-provincial
B1↔A11.2 GWinter-provincial
A1↔S10.15 GWinter-provincial
S1↔M10.25 GWinter-provincial
M1↔O10.3 GWinter-provincial
O1↔Q12.7 GWinter-provincial
Q1↔T11.1 GWinter-provincial
Q2↔L15.4 GWinter-provincial
T1↔L10.5 GWinter-provincial

Provincial policy

Expressed with User Defined Constraints over groups of technologies: Σ(multiplier × activity) ⋛ UDCConstant. Full formulation in the model & code page; the Policies page inventories the federal & provincial policies this represents.

No provincial policies are active. Declare them in model_structure.ProvincialPolicies and they become UDC rows automatically.